Download, testing and diagnostics
CPU 317T: Technology Functions
A5E00251798-03
8-43
To move an axis using the axis control panel:
1. Click "Details".
2. Click "Enable axis".
Check that all enabling signals have been set and followup mode canceled in
the displayed window. Confirm with "OK".
3. Click the button of a motion command (Velocity preset, Start axis position-
controlled, Position axis or Home axis).
In the next dialog box, enter the parameters. Confirm with "OK".
4. Set override at the "Speed Override" shift register to an acceptable value.
5. Click "Start".
The axis starts to move.
While the axis is moving, you can alter the velocity override factor.
6. To stop the motion, click "Stop" or press the space bar.
You can continue the movement by clicking "Start."
7. Repeat steps 3 to 6 as required.
Note
When using the "Velocity preset" and "Start axis positioncontrolled" commands,
you can also start the motion by cl
icking "Jog." Keep the left mouse button pressed
while the motion is to continue. The motion stops when the mouse button is
released.
You can also stop the axis by pressing the space bar.