Technology functions
CPU 317T: Technology Functions
A5E00251798-03
6-25
6.2.4 FB 405 MC_Halt - Normal stop
Purpose
The "MC_Halt" technology function stops all motions and ramps the axis down
to standstill.
At the input parameters Jerk and Deceleration, you determine the dynamic
response within the stop operation.
The command is terminated when the axis has reached a standstill, or is
canceled by a new motion command.
The standstill position is not defined.
Applicable to
Velocity axes
Positioning axes
Synchronization axes
Requirements
The axis is enabled for velocity and position control