CPU 317T: Technology Functions
A-38 A5E00251798-03
No. Name
(standard in S7T Config)
Name
(Expert list in S7T Config)
Data type Index min. max. Access
Active D P V Description
1354 Monitoring Standstill signal
Speed limit
TypeOfAxis. StandStillSignal.
maxVeloStandStill
REAL - -1E+12 1E+12 R, W Immediately X X X Standstill speed limit
1400 Position control Static
controller data Control variable
limiting. Activation
TypeOfAxis.SpeedLimitation.
Enable
DINT Enum
AxisFilterMode
- - - R, W Restart X X X Enable status of speed range
limit
1402 Position control Static
controller data Control variable
limiting. Low limit
TypeOfAxis.SpeedLimitation.
MinSpeed
REAL - -1E+12 1E+12 R, W Immediately X X X Low speed limit
1403 Position control Static
controller data Control variable
limiting. High limit
TypeOfAxis.SpeedLimitation.
MaxSpeed
REAL - -1E+12 1E+12 R, W Immediately X X X High speed limit