Connect Tech CPU Manuel de service Page 182

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 650
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 181
Configuration
CPU 317T: Technology Functions
4-106 A5E00251798-03
4.9 Configuring measuring sensors
Before a measuring sensor is used in the user program, the measuring sensor first
has to be inserted in S7T Config as a "Measuring sensor" technology object.
The function is programmed in the user program at FB "MC_MeasuringInput".
There you enable and disable the measuring sensor in the various operating
modes and define its measuring range. The association to the measuring sensor
created in S7T Config is set at the MeasuringInput input, by entering the number of
the relevant technology DB.
4.9.1 Adding a measuring sensor
Requirements
The data of the Technology CPU are configured in HW Config and are
compiled.
An axis or external encoder was created in S7T Config.
How to add a measuring sensor in S7T Config
Step Description
1.
In the S7T Config navigator, double-click "Insert measuring input".
Vue de la page 181