Connect Tech CPU Manuel de service Page 160

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 650
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 159
Configuration
CPU 317T: Technology Functions
4-84 A5E00251798-03
The sense of the synchronization movement is set in the "Synchronization
direction" drop-down list. This setting is only available for modulo axes.
Setting Meaning
User default / default The default value can be set by means of the following configuration
data in the expert list:
Setting for gearing:
userdefault.gearingsettings.synchronizingdirection
(parameter 4291 for MC_ReadSysParamter, MC_WriteParameter)
Settings for camming:
userdefault.cammingsettings.synchronizingdirection
(parameter 4270 for MC_ReadSysParamter, MC_WriteParameter)
Compatibility mode Same reaction as in Version 3.0.x of the firmware of the integrated
technology.
Shortest distance without
direction preset
The following axis is synchronized within the shortest possible
distance.
Negative direction of the
synchronization motion
The direction of the synchronization motion is always negative.
Positive direction of the
synchronization motion
The direction of the synchronization motion is always positive
Maintain the direction of the
following axis
Synchronization is always determined by the direction of the following
axis motion.
Vue de la page 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 649 650

Commentaires sur ces manuels

Pas de commentaire