Configuration
CPU 317T: Technology Functions
4-64 A5E00251798-03
4.5.8.4 Standstill signal
Select the "Standstill signal" tab of the Axis > Monitoring functions dialog box to
set the velocity threshold and delay time.
The standstill signal sets the "Standstill" bit in the status word of the technology
DB, if the current velocity is below the configured velocity threshold at least for the
duration of the set delay time.
At velocity-controlled and positioning axes, this override takes place in velocity-
controlled operation. At the positioning axis, the override is triggered when it
reaches the positioning window.