Connect Tech FreeForm/PCI-104 User Manual
Revision 0.07 28
6) Right click on the flash and perform a blank check.
7) If the part is blank you will see:
INFO:iMPACT - Current time: 2013-03-25 3:24:31 PM
// *** BATCH CMD : BlankCheck -p 1 -spionly
PROGRESS_START - Starting Operation.
Maximum TCK operating frequency for this device chain: 10000000.
Validating chain...
Boundary-scan chain validated successfully.
1: Device Temperature: Current Reading: -273.00 C
1: VCCINT Supply: Current Reading: 0.000 V
1: VCCAUX Supply: Current Reading: 0.000 V
'1': IDCODE is '202016' (in hex).
'1': ID Check passed.
'1': IDCODE is '202016' (in hex).
'1': ID Check passed.
'1': Performing blank check on device...
'1': Part is blank.
PROGRESS_END - End Operation.
Elapsed time = 65 sec.
8) Right click on the flash and click Program