11) Right click on the second device in the JTAG chain and click Assign New Configuration File
12) Browse to the bsdl folder and select PCI9056BA.bsd
Example: {REFDIR}\fpga\bsdl\PCI9056BA.bsd
13) Right click on the second device in the JTAG chain and click Assign New Configuration File
14) Browse to the bsdl folder and select DP83849IVS.bsd.
Example: {REFDIR}\fpga\bsdl\ DP83849IVS.bsd
15) To test stream integrity, right click on the FPGA and select Get Device ID. The console will
report Manufacturer's ID = Xilinx xc5vlx30t
INFO:iMPACT - Current time: 2013-03-25 3:01:12 PM
// *** BATCH CMD : ReadIdcode -p 1
Maximum TCK operating frequency for this device chain: 10000000.
Validating chain...
Boundary-scan chain validated successfully.
1: Device Temperature: Current Reading: -273.00 C
1: VCCINT Supply: Current Reading: 0.000 V
1: VCCAUX Supply: Current Reading: 0.000 V
'1': IDCODE is '11000010101001101110000010010011'
'1': IDCODE is 'c2a6e093' (in hex).
'1': : Manufacturer's ID = Xilinx xc5vlx30t, Version : 12
16) Save the iMPACT project (File -> Save Project As)
Example: {REFDIR}\fpga\\ise_projects\ref_design_fcg001rd\ ref_design_fcg001rd.ipf